DCP
Showing all 5 results
-
DCP, UPS
DCP 3000VA
Model: D1200
Capacity: 3000VA / 1800W
Input Voltage: 220V / 230V
Input Voltage Range: 160–300V AC
Input Frequency: 50 or 60 Hz (auto-sensing)
Output Power Factor: 0.6
Output Voltage (Battery): 220V / 230V ±10%
Output Waveform (Battery): Simulated sine wave (PWM)
Output Frequency (Battery): 50 or 60 Hz ±1Hz
Automatic Voltage Regulation (AVR)
Transfer Time: 2–6 ms
Output Sockets: 4 × Universal sockets
Battery Type: Maintenance-free lead acid batteries
Nominal DC Voltage: 12VDC
Battery Quantity: 4 × 12V 9Ah
Battery Charge Duration: Approx. 5 hours (90% capacity)
Backup Time: 7–20 minutes (depending on connected load)SKU: n/a -
DCP, UPS
DCP D1200
Model: D1200
Capacity: 1200VA / 720W
Input Voltage: 220V / 230V
Input Voltage Range: 140–300V AC
Input Frequency: 50 or 60 Hz (auto-sensing)
Output Power Factor: 0.6
Output Voltage (Battery): 220V / 230V ±10%
Output Waveform (Battery): Simulated sine wave (PWM)
Output Frequency (Battery): 50 or 60 Hz ±1Hz
Automatic Voltage Regulation (AVR)
Transfer Time: 2–6 ms
Output Sockets: 4 × Universal sockets
Battery Type: Maintenance-free lead acid batteries
Nominal DC Voltage: 12VDC
Battery Quantity: 2 × 12V 7Ah
Battery Charge Duration: Approx. 5 hours (90% capacity)
Backup Time: 7–20 minutes (depending on connected load)SKU: n/a -
DCP, UPS
DCP D700
Model: D700 Line Interactive UPS
Capacity: 650VA
Input Voltage: 220V / 230V AC
Input Voltage Range: 160–300V AC
Input Frequency: 50 or 60 Hz (auto-sensing)
Output Power Factor: 0.6
Output Voltage (Battery Mode): 220V / 230V ±10%
Output Waveform: Simulated sine wave (PWM)
Output Frequency (Battery Mode): 50 or 60 Hz ±1HzAutomatic Voltage Regulation (AVR) for voltage stabilization
Transfer Time: 2–6 ms
Output Sockets: 2 × Universal sockets
Battery Type: Maintenance-free sealed lead acid
Battery Capacity: 1 × 12V 7Ah
Charging Time: Approx. 5 hours (to 90% capacity)SKU: n/a -
DCP, UPS
DCP 2000VA
Model: D1200
Capacity: 2000VA / 1200W
Input Voltage: 220V / 230V
Input Voltage Range: 160–300V AC
Input Frequency: 50 or 60 Hz (auto-sensing)
Output Power Factor: 0.6
Output Voltage (Battery): 220V / 230V ±10%
Output Waveform (Battery): Simulated sine wave (PWM)
Output Frequency (Battery): 50 or 60 Hz ±1Hz
Automatic Voltage Regulation (AVR)
Transfer Time: 2–6 ms
Output Sockets: 4 × Universal sockets
Battery Type: Maintenance-free lead acid batteries
Nominal DC Voltage: 12VDC
Battery Quantity: 2 × 12V 9Ah
Battery Charge Duration: Approx. 5 hours (90% capacity)
Backup Time: 7–20 minutes (depending on connected load)SKU: n/a -
DCP, UPS
DCP Power 1KVA
Model: DCP Power 1KVA
Capacity: 1000VA / 1000W
High-frequency on-line double conversion technology
DSP (Digital Signal Processing) control technology
Active Power Factor Correction (APFC) with input power factor up to 0.99
Output power factor 0.9 / 1.0
Wide input voltage range: 110V – 300V AC
Wide input frequency range: 40 – 70 Hz
Auto-sensing frequency
50 / 60 Hz frequency conversion
Cold start function
Rear ventilation design with variable-speed fan
Effective software and hardware protection
Fast and stable charging, 90% capacity restored in 3 hours (standard model UPS)SKU: n/a